Model NO.: GD-9239
Trademark: Gold
Transport Package: Standard Wooden Case
Specification: 200kg
Origin: Chongqing, China
HS Code: 9031809090
GD-9239 Flooring Radiant Panel Test EquipmentÂ
       Â

Introduction
This surface of the material spread flame tester (ISO 9239, Flooring Radiant Panel Tester) is test method that formal reflected spread of flame on flooring material back-draft condition when fire on building happened flame at compartment or room adjacent, or high temperature gas radiated to flooring surface a hot radiation heat accumulated at upper of midway during a fire at an early growing step.Â
More detail as see the next view; specimen is located at down horizon of 30 degree sloped gas radiation panel per horizon surface.Â
Pilot flame as ignition resource put a part edge of specimen on high temperature side. This equipment record ignition time by spark, moving time which flame horizontal pass by specimen of length.

Standard
• ISO 9239-1:Reaction to Fire Tests for Floorings - Part 1:Determination of the Burning Behavior Using a Radiant Heat SourceÂ
• ISO 9239-2 : Reaction to Fire Tests for Floorings - Part 2 : Determination of Flame Spread at a Heat Flux Level of 25kw/m2.Â
• ASTM E 648 : Standard Test Method for Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat Energy SourceÂ
• ASTM E 970 : Standard Test Method for Critical Radiant Flux of Exposed at Attic Floor Insulation Using a Radiant Heat Energy SourceÂ
• NFPA 253 : Standard Method of Test for Critical Radiant Flux of Floor Covering Systems Using a Radiant Heat Energy Source (National Fire Codes, Vol.6)Â
• KS F ISO 9239-1 : Reaction to Fire Tests for Floorings - Part 1 : Determination of the Burning Behavior Using a Radiant Heat SourceÂ
• KS F ISO 9239-2: Reaction to Fire Tests for Floorings - Part 2 : Determination of Flame Spread at a Heat Flux Level of 25kw/m2.
Specification
- Steel frame chamber:1400(W)×500(D)×2,220(H)Â
- Calcium silicate insulation boardÂ
- Observation windowÂ
- Sliding platform for loading of the test specimenÂ
- Radiant Panel:300±10mm × 450±10mm (30°, Porous cement)Â
- Auto moving ignition burnerÂ
- Scale for check flame spreadÂ
- K-type thermocouples : Range, Ambient ~ 1,500ºCÂ
- Stainless steel sample holdersÂ
- Dummy calibration panel holders for measuring heat fluxmeterÂ
- Pyrometer for measuring radiant panel temperatureÂ
- Exhaust duct & hood: Ø 300 / (W)1,700 x (D)1,200 x (H)400 mmÂ
- Heat Flux MeterÂ
 Range : 0 ~ 100 ± 10 kw/m2;Â
 Surface emissivity : ε=0.95± 0.05;Â
- DAQ(Data Acquisition) systemÂ
 NI-PCI DAQ Board;Â
 16 Bit wide gain rage, Analog and Digital I/O Board;Â
 Three A/D trigger modes;Â